Page 204 - THE FIRE STATION
P. 204
202
their relative importance is all the more crucial.They are also likely Example 2:Thermal break used for the anchors of the sheeting
to cause risks with respect to the building’s physics and hygiene surrounding the building
(formation of surface condensation and the emergence of mould).
Risk-bearing joints are therefore looked at in detail. Solution:Thermal break using a 50 mm block of purenit©
(high-density PUR 3) for each anchor.
Example 1: Emergency response vehicle exit 1) Detail
Solution: Use of neoprene tapes (compression-resistant) 2) Modelling
for sealing the joint between the inside floor slab and the 3) Calculation and optimisation
outside slab. 4) Implementation
1)Technical detail
2) Finite element modelling 2
3) Identification of high thermal flows
4) Isotherms
2
1
12 34
34
– The positioning and properties of the windows and glazing play
a major role in increasing the comfort of a building’s occupants.
A glazed opening must first and foremost provide visual comfort
through establishing a link between inside and outside. Glare
needs to be monitored and the amount of natural light maximized
to reduce the need for artificial lighting.
Fig. 4: 3D modelling of the gym and visua-
lisation of the results (Autodesk Ecotect
Analysis©)