Reference
title
BReeam europe: offices Criteria
Number of BReeam credits available
total BReeam credits achieved
ffdaidalos
hEA 11
Thermal zoning
One credit where evidence provided demonstrates that local occupant control is available for temperature adjustment in each occupied space to reflect differ- ing user demands.
1
0
Fti
hEA 12
Microbial contamination
One credit where evidence provided demonstrates that the risk of waterborne and airborne legionella contamination has been minimized.
1
0
daidalos
hEA 13
Acoustic performance
One credit where evidence provided demonstrates that the building achieves appropriate indoor ambient noise levels in offices areas. In addition, for fully fitted buildings only: appropriate airborne sound insulation levels are achieved between acoustically sensitive spaces and occupied spaces, sufficient to ensure adequate privacy.
1
1
eNeRGY
fffffdaidalos / Fti
ENE 1
Energy efficiency
Up to 15 credits where evidence provided demonstrates an improvement in the energy performance of the buildings's fabric and service based on the percentage improvement in the assessed designs' predicted Build-
ing Energy Performance Index (BEPI) over the Current Standards Build-
ing Energy Performance Index (CSBEPI), as defined for the local Energy Performance Certificate, OR up to 15 credits where there is no operational National energy Calculation Methodology (NCM) in the country of assess- ment, evidence provided demonstrates an improvement in the energy performance efficiency of the building's fabric and services through the use of a recognized energy Dynamic Simulation Modelling (DSM) software, OR up to 10 credits where there is no NCM in the country of assessment, evi- dence provided demonstrates an improvement in the energy efficiency of the building's fabric and services using Checklist A7 and that the building achieves lower operational related CO2 emissions.
15
10
Fti
ENE 2
Sub-metering of substan- tial energy uses
One credit where evidence provided demonstrates the provision of direct sub-metering of energy uses within the building.
1
1
Fti
ENE 3
Sub-metering of high energy load areas and tenancy
One credit where evidence provided demonstrates sub-metering of energy consumption by tenancy/building function area is installed within the build- ing.
1
1
Fti
ENE 4
External lighting
One credit where energy-efficient external lighting is specified and all light fittings are controlled for the presence of daylight.
1
1
daidalos
ENE 5
Low or Zero Carbon (LZC) technologies
One credit where evidence provided demonstrates that a feasibility study considering local (on-site and/or near site) LZC technologies has been car- ried out and the results implemented.Two credits where evidence provided demonstrates that the first credit has been achieved and there is a 10% reduction in the building’s CO2 emissions as a result of the installation
of feasible local LZC technology.Three credits where evidence provided demonstrates that the first credit has been achieved and there is a 15% reduction in the building’s CO2 emissions as a result of the installation of feasible local LZC technology. Or alternatively: A maximum of one credit where evidence provided demonstrates that a contract with an energy supplier is in place to provide sufficient electricity used within the assessed building/development to meet the above criteria from a 100% renewable energy source. (Note: a standard GreenTariff will not comply.)
3
3
Fti
ENE 8
Lifts
Up to 2 credits are available where evidence provided demonstrates the installation of energy-efficient lift(s).
2
2
fffffffffftRaNsPoRt
BoPRo
TRA 1
Provision of public transport
Up to 4 credits can be awarded based on the proximity of the development to a public transport node with a good service frequency. Determined using the BREEAM Public Transport Table.
2
2
BoPRo
TRA 2
Proximity to amenities
One credit where evidence provided demonstrates that the building is lo- cated within 500 m of accessible local amenities appropriate to the building type and its users.
1
1
sai & Beai
TRA 3
Alternative modes of transport
Two credits can be awarded where one of the following measures has been implemented to encourage the use of alternatives to the private car for commuting. Option 1: provision of compliant cycle storage spaces accord- ing to the number of building users and of compliant facilities including showers, changing facilities and lockers for clothes and drying space for wet clothes. Option 2: cooperation with the local authority for the develop- ment and implementation of a proposition to improve the local cycling network. Option 3: negotiations with local bus companies have resulted in an increase of the local service provision in the development’s local area. Option 4: provision of electric recharging stations using electricity from
a renewable source. Option 5: development and implementation of a car sharing platform as well as adequate car parking capacity and spaces.
2