Page 245 - AGC_MultiLingue_HD.indd
P. 245
245
Responsible parties
Reference
title
BReeam europe: ofices Criteria
Number of BReeam credits available
total BReeam credits achieved
maNaGemeNt
seCo / axa
MAN 1
Commissioning
One credit where evidence provided demonstrates that suficient time and resources will be allocated for commissioning prior to handover in the construction programme to ensure eficient operation of all the services within the building.Two credits where, in addition to the above, evidence provided demonstrates that commissioning will be carried out in line with best-practice commissioning codes and that seasonal commissioning will be carried out during the irst year of occupation, post construction (or post it-out).
2
2
Van Roey
MAN 2
Constructors' environmental code of conduct
One credit where evidence provided demonstrates that there is a commit- ment to comply with best-practice site management principles.Two credits where evidence provided demonstrates that there is a commitment to go beyond best-practice site management principles.
2
2
Van Roey
MAN 3
Construction site impacts
One credit where evidence provided demonstrates that 2 or more of items a-g (listed below) are achieved.Two credits where evidence provided demonstrates that 4 or more of items a-g (listed below) are achieved.Three credits where evidence provided demonstrates that 6 or more of items a-g are achieved. a) Monitor, report and set targets for CO2 or energy arising from site activities. b) Monitor, report and set targets for CO2 or energy arising from transport to and from site. c) Monitor, report and set targets for water consumption arising from site activities. d) Implement best- practice policies in respect of air (dust) pollution arising from the site. e) Implement best-practice policies in respect of water (ground and surface) pollution occurring on site. f) Main contractor has an environmental materi- als policy, used for sourcing of construction materials to be utilized on site. g) Main contractor operates an Environmental Management System. One additional credit where evidence provided demonstrates that at least 80% of site timber is responsibly sourced and 100% is legally sourced.
4
3
axa
MAN 4
Building user guide
One credit where evidence provided demonstrates the provision of a simple guide that covers information relevant to the tenant/occupants and non-technical building manager on the operation and environmental performance of the building.
1
1
Bopro
MAN 12
Life Cycle Cost (LCC) analysis
One credit where evidence provided demonstrates that a Life Cycle Cost (LCC) analysis based on the feasibility study proposals has been undertaken on the building design at a strategic and system level.Two credits where, in addition to the above, evidence provided demonstrates that the results of the feasibility study and consideration of LCC have been implemented.
2
2
HeaLtH & WeLLBeiNG
sai / daidalos / Fti
hEA 1
Daylighting
One credit where evidence provided demonstrates that at least 80% of loor area in each occupied space receives adequate daylight.
1
0
sai
hEA 2
View out
One credit where evidence provided demonstrates that all relevant building areas have an adequate view out.
1
1
sai & Beai
hEA 3
Glare control
One credit where evidence provided demonstrates that an occupant-controlled shading system (e.g., internal or external blinds) is itted in relevant building areas.
1
1
Fti / daidalos
hEA 4
high frequency lighting
One credit where evidence provided demonstrates that high-frequency ballasts are installed on all luorescent and compact luorescent lamps.
1
1
Fti / daidalos
hEA 5
Internal and external lighting levels
One credit where evidence provided demonstrates that all internal and external lighting, where relevant, is speciied in accordance with the appropriate illumi- nance levels (in lux) in accordance with national best-practice guides.
1
1
sai & Beai / Fti
hEA 6
Lighting zones and controls
One credit where evidence provided demonstrates that, in all relevant building areas, lighting is appropriately zoned and occupant-controllable.
1
1
sai & Beai
hEA 7
Potential for natural ventilation
One credit where evidence provided demonstrates that fresh air is capable of being delivered to the occupied spaces of the building via a natural ventilation strategy, and there is suficient user-control of the supply of fresh air.
1
1
hEA 8
Indoor air quality
One credit where air intakes serving occupied areas avoid major sources of external pollution and recirculation of exhaust air.
1
0
sai & Beai / Van Roey
hEA 9
Volatile Organic Compounds (VOCs)
One credit where evidence provided demonstrates that the emissions of VOCs and other substances from key internal inishes and ittings comply with best- practice levels.
1
1
daidalos
hEA 10
Thermal comfort
One credit where evidence provided demonstrates that an analytical measure- ment and evaluation of the thermal comfort levels of the building has been car- ried out using the PMV and PPD indices in accordance with EN ISO 7730:2005. Two credits where evidence provided demonstrates that thermal comfort levels in occupied spaces of the building are assessed at the design stage to evaluate appropiate servicing options, ensuring appropiate thermal comfort levels are achieved.
2
2


































































































   243   244   245   246   247